Installation

Table 3 (continued)

Country

 

 

Supply

Injector

Capacity/

Diameter,

 

Injector

Gas Type

Group

Pressure,

Pressure,

Quantity

Code

Model

mm

Part No.

 

 

mbar

mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

20

7.6

25

3.9

1

M402980

 

 

 

 

8.0

30

4.0

1

M402992

GB/IE/PT/

 

 

 

8.0

T30

4.0

2

M402992

 

 

 

8.0

35

4.6

1

M411511

ES/IT/GR/

 

 

 

 

 

 

 

 

L.P. Gas

+

28 or 37

No Governor

25

2.1

1

M401003

LU/CH

 

 

 

 

 

30

2.2

1

M401011

 

 

 

 

 

T30

2.2

2

M401011

 

 

 

 

 

35

2.5

1

M406361

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

20

7.6

25

3.9

1

M402980

 

 

 

 

8.0

30

4.0

1

M402992

 

 

 

 

8.0

T30

4.0

2

M402992

AT**

 

 

 

8.0

35

4.6

1

M411511

 

 

 

 

 

 

 

 

L.P. Gas

B/P

50**

28**

25

2.1

1

M401003

 

 

 

 

 

 

30

2.2

1

M401011

 

 

 

 

 

T30

2.2

2

M401011

 

 

 

 

 

35

2.5

1

M406361

 

 

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

No Governor

25

2.1

1

M401003

CY/IS/MT

 

 

 

 

30

2.2

1

M401011

 

 

 

 

T30

2.2

2

M401011

 

 

 

 

 

 

 

 

 

 

35

2.5

1

M406361

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

25

7.6

25

3.9

1

M402980

 

 

 

 

8.0

30

4.0

1

M402992

 

 

 

 

8.0

T30

4.0

2

M402992

HU

 

 

 

8.0

35

4.6

1

M411511

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

No Governor

25

2.1

1

M401003

 

 

 

 

 

 

30

2.2

1

M401011

 

 

 

 

 

T30

2.2

2

M401011

 

 

 

 

 

35

2.5

1

M406361

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

20

7.6

25

3.9

1

M402980

 

 

 

 

8.0

30

4.0

1

M402992

 

 

 

 

8.0

T30

4.0

2

M402992

PL

 

 

 

8.0

35

4.6

1

M411511

 

 

 

 

 

 

 

 

L.P. Gas

3P

37

No Governor

25

2.1

1

M401003

 

 

 

 

 

 

30

2.2

1

M401011

 

 

 

 

 

T30

2.2

2

M401011

 

 

 

 

 

35

2.5

1

M406361

 

 

 

 

 

 

 

 

 

Injector information at 0-2000 feet (0-600 meters) altitude.

*For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace injectors.

**For L.P. Gas, Group B/P with 50 mbar supply pressure, convert using Natural Gas model, 431559 regulator spring kit and injectors.

28

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70269701