Installation

Pre-Installation Inspection

Upon delivery, visually inspect crate carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.

Remove the crate and protective cover as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.

IMPORTANT: Warranty is void unless tumbler is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed herein, and with applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.

Material Required (Obtain Locally)

All Models One disconnect switch or circuit breaker.

Location Requirements

The tumbler must be installed on a level floor capable of supporting weight of tumbler fully loaded. Floor covering materials such as carpeting or tile should be removed.

To assure compliance, consult local building code requirements. The tumbler must not be installed or stored in an area where it will be exposed to water and/or weather.

IMPORTANT: DO NOT block the airflow at the rear of the tumbler with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumbler.

A typical tumbler enclosure is shown in Figure 1. Note the minimum and maximum dimensions. Local codes and ordinances must be complied with.

WARNING

To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.

W055

IMPORTANT: Install tumblers with sufficient clearance for servicing and operation. Refer to Figure 1.

IMPORTANT: Keep tumbler area clear and free from combustible materials, gasoline and other

Gas Models

One gas shut-off valve for gas service line to each tumbler.

flammable vapors and liquids.

Steam One steam shut-off valve for steam

Models service line to be connected upstream of solenoid steam valve.

Steam shut-off valve for each condensate return line.

Flexible steam hoses with a 125 psig (pounds per square inch gauge)

(8.78 kg/sq. cm) working pressure for connecting steam coils. Refer to Figure 15 for sizing and connection configurations.

Steam trap for steam coil outlet to condensate return line.

Optional – Vacuum breaker for condensate return line.