How to Change Injector (Orifice) Size

1.Disconnect electrical power from tumbler. Close gas shut-off valve to tumbler. Refer to Figure 6.

2.For Johnson GM7000 gas valve:

Remove burner orifice(s) from the spud holder. Refer to Figure 7.

3.Install the new, correct injector(s) (orifices). Refer to Figure 8. Torque each to 9 – 10 Nm.

4.Commission tumbler for use.

NOTE: Blank injectors (orifices) are available as Part No. M400995.

Installation

How to Adjust Gas Valve Governor/Regulator

1. Check gas injector (manifold) pressure as follows. Refer to Figure 7.

2. Loosen screw plug inside pressure tap located on underside of valve.

3. Connect a “U”-tube manometer (or similar pressure gauge) to the tap.

4. Start tumbler and note pressure once flame is

burning. Remove regulator cap and adjust regulator screw until the injector pressure per applicable table is achieved. Replace regulator cap and close needle valve (pressure tap).

5. Commission tumbler for use.

1

BURNER INJECTOR

(ORIFICE)

TMB2015N

1Size Stamped on Orifice

Figure 8

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

31