Alto-Shaam QC-3/QC-20/QC-40/QC-50/QC-50 Remote/QC-100/Qc-100 Remote Advancedsub Title Operation

Models: QC-3/QC-20/QC-40/QC-50/QC-50 Remote/QC-100/Qc-100 Remote

1 60
Download 60 pages 22.76 Kb
Page 20
Image 20
ADVANCEDSUB TITLE OPERATION

O P ETRITALTEI O N

ADVANCEDSUB TITLE OPERATION

The date and time will appear in the display when the unit is off. When the unit is turned on, the screen will read: “SELECT MODE OR PRESS START TO SELECT PRESET

To initiate any Quickchiller operating mode, power must initially start from the off position or an operating mode must be halted by pressing the START/STOP key so that the SELECTION SCREEN appears on the display.

NOTE: With the exception of the QC-3 counter top Quickchiller model, the Alto-Shaam name on the control panel will illuminate whenever the power key is pressed to the on position.

HOLD TEMP

Starting from the off position, press the power key on. The SELECTION SCREEN will appear on the display. The compressor will become energized and will begin to operate if required by the sensors.

Press the HOLD TEMP key. The display will indicate the default hold temperature (changeable in User Settings).

To change the displayed temperature, press the up5or down6arrow key to increase or decrease the temperature display within the refrigeration storage parameters of the Hold Temp mode -5°F to +40°F (-21°C to +4°C).

note: the modified holding temperature set-point is not saved. the default hold temperature can be changed under user settings.

Press the START/STOP key to begin operation of the Quickchiller in the Hold Temp mode.

The display will indicate:

1.The length of time the chiller is operating in the Hold Temp mode.

2.The temperature set by the operator.

3.The air temperature inside the chiller compartment.

4.The temperature of all food probes.

WHEN IN THE HOLD TEMP MODE AFTER A CHILL MODE:

Press the UP 5arrow key to display the maximum sensor temperature achieved during the completed chill cycle. Press the DOWN 6 arrow key to display the minimum sensor temperature achieved during the completed chill cycle. Press the right4or left3arrow key to display the Probe Done Time.

C A U T I O N

NEVER STACK PANS DIRECTLY

ON TOP OF EACH OTHER.

STACKED PANS WILL RESTRICT

AIR FLOW AND INCREASE CHILL

PROCESSING TIME.

C A U T I O N

ADEQUATE SPACING MUST

BE ALLOWED BETWEEN PANS

FOR PROPER AIR CIRCULATION

FOR BOTH PROCESSING AND

SUBSEQUENT HOLDING.

QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 18 .

Page 20
Image 20
Alto-Shaam QC-3/QC-20/QC-40/QC-50/QC-50 Remote/QC-100/Qc-100 Remote Advancedsub Title Operation, Hold Temp, C A U T I O N