INSTALLATION REQUIREMENTS

I N S T A L L A T I O N

SITE INSTALLATION

INSTALLATION REQUIREMENTS

The model QC-3 is a counter mounted unit and must be sealed to the counter with a NSF listed silicone sealant.

For all other

models, install

the appliance on a smooth and

level floor surface. Use the adjustable cabinet legs to level the Quickchiller.

Adjust from front-to-back and from side-to-side with the use of a spirit level to evenly distribute the cabinet weight and avoid pulling the cabinet alignment out of square.

After leveling the cabinet of cart equipped models, check the height relationship of the roll-in cart

to the cabinet. Adjust the Quickchiller height as needed to accommodate the cart and to securely close the Quickchiller door(s).

DOOR SEAL:

Check the door gasket to make certain it is sealing properly and that the gasket provides an even and positive seal around the entire door frame.

C A U T I O N

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

WATER DRAINAGE

DRAINAGE:

QC-3

QC-20

QC-40

 

 

 

EVAPORATOR PANS: NO INSTALLATION REQUIRED

QC-50

QC-100

 

 

ONE (1) FLOOR DRAIN: 1/2" (12,7mm) DIAMETER

A 1/2" I.D. (12,7mm) PVC pipe is furnished with each QC-50 and QC-100 model. Use PVC glue to attach the pipe into the drain opening at the rear of the unit. Insert the PVC pipe into the drain opening with a 1/4" (6mm) clockwise turn. Connect the PVC pipe to discharge through an indirect waste pipe into an open-site drain by means of a 2" (51mm) air gap. Connection must be within 10' (3m) of the unit.

NOTE: In the U.S.A., this equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code­ Administrators International, Inc. [BOCA], and the Food Service Sanitation Manual of the Food & Drug Administration [FDA].

drain opening

at rear

QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 4 .