Checking Unit and Drive Status

Enclosure LED Status Indicators

The LEDs on your enclosure also provide status information about your drives and units.

Table 8: Meaning of LED Colors and Behavior

Color

Drive Status

 

 

Solid green

OK

 

 

Blinking green

Identify

 

This occurs when you have used the Identify command in 3DM

 

to locate a particular drive or unit. (See “Locating a Drive by

 

Blinking Its LED” on page 81.)

 

 

Black

No drive

 

 

Solid Amber

Hot spare

 

 

Blinking amber

Rebuilding

 

The drive in this slot is part of a RAID unit that is currently

 

rebuilding. You can continue to use the unit. For more

 

information, see “Rebuilding Units” on page 73.

 

 

Solid red

Drive fault

 

This drive has failed. You should replace it and rebuild the unit.

 

 

Blinking red

Predicted drive fault

 

3ware software predicts that this drive will fail soon. You may

 

want to replace it.

 

 

Unit Statuses

The following is a list of unit statuses you may see in 3DM:

OK. The unit is optimal and is functioning normally.

Rebuilding. The unit is in the process of writing data to a newly added disk in a redundant unit, in order to restore the unit to an optimal state. The unit is not fully fault tolerant until the rebuilding is complete. For more information, see “Rebuilding Units” on page 73.

Rebuild-Paused.The unit is set to rebuild, however scheduling is enabled, and the present time is not during a scheduled timeslot. Rebuilding will start at the next scheduled time slot. Rebuilds are also paused for up to ten minutes after a reboot, even during a scheduled timeslot.

www.3ware.com

63

Page 71
Image 71
AMCC 720-0138-00 manual Enclosure LED Status Indicators, Unit Statuses