Changing An Existing Configuration

Figure 22. RAID Level Migration Example

Typically, a unit is reconfigured with the same or more storage capacity. Sometimes additional drives are added. The following table shows valid reconfigurations, some of which will require the addition of more drives.

Table 7: Valid Migration Paths

 

 

 

Destination

 

 

 

 

 

 

 

 

 

Source

R0

R1

R5

R10

Single

Spare

 

 

 

 

 

 

 

R0

Yes

No

Yes

Yes

No

No

 

 

 

 

 

 

 

R1

Yes

No

Yes

Yes

Yes

No

 

 

 

 

 

 

 

R5

Yes

No

Yes

Yes

No

No

 

 

 

 

 

 

 

R10

Yes

No

Yes

Yesa

No

No

Single

Yes

Yes

Yes

Yes

No

No

 

 

 

 

 

 

 

Spare

No

No

No

No

No

No

 

 

 

 

 

 

 

a.When migrating a RAID 10 to a RAID 10, the only change you can make is the stripe size.