C. L.E.D. CODES

1.Display Codes

A

ALL REV

ANTI WRINKL dELAY TIME ANTI WRINKL GUARd ACTIVE ANTI WRINKL GUARd ON TIME AUTO CYCLE

b

bURNER CONTROL FAIL bURNER FLAME FAIL bURNER SAFETY FAIL bUZZ

bUZZ TIME CEL

CHECK MAIN FUSE CLEAN LINT COOL

COOL TIME_M

COOL TEMP_ CYCLEA CYCLEb

CYCLEC

CYCLED

CYCLEE

CYCLEF dONE dRYING dRY LEVEL_ dRY TEMP F_ dRY TIME_M

dRUM SAFETY FAIL ELAPSE TIME_MIN ELECTRIC

F FAR FLASH GAS HOT LINT dOOR

LINT COUNT

_M REMAIN MAIN dOOR

MANUAL CYCLE

MAX ANTI WINKL GUARd

NFLASH NoAIR FLOW

NoANTI WRINKL GUARd NoBUZZ

NoHEAT

NoREV

No ROTATE SENSOR PROGRAM REAdY

ROTATE SENSOR ACTIVE ROTATE SENSOR FAIL _RPM

SAIL SWITCH FAIL

SELREV SPIN TIME START GUARd

STEAM STOP TIME

TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE

SLOPE FACTOR ALWAYS REVERSING ANTI-WRINKLE DELAY TIME

ANTI-WRINKLE PROGRAM ACTIVE

ANTI-WRINKLE GUARD ON TIME AUTOMATIC MODE

HEAT LOSS (OFF SET) FACTOR

GAS ONLY POWER (24VAC) IS NOT EVIDENTAT GAS VALVE NO BURNER FLAME SENSED

GAS/ELECTRIC ONLY BURNER/OVEN OPEN HI-LIMIT CIRCUIT BUZZER (TONE)

BUZ TIME

DEGREE IN CELSIUS

MAIN FUSE FAILURE

PROMPT TO CLEAN LINT SCREEN, DRYER CYCLE LOCK-OUT COOL DOWN CYCLE IN PROGRESS

COOL DOWN TIME

COOL DOWN TEMPERATURE

PREPROGRAMMED CYCLE A

PREPROGRAMMED CYCLE B

PREPROGRAMMED CYCLE C

PREPROGRAMMED CYCLE D

PREPROGRAMMED CYCLE E

PREPROGRAMMED CYCLE F

DRYING or COOLING CYCLE COMPLETE OR DRYER INANTI-WRINKLE MODE DRYINGCYCLEINPROGRESS

DRYNESS LEVEL(PERCENTAGE OF EXTRACTION) (NUMERICALVALUE) DRYING TEMPERATURE

LENGTH OF DRYING CYCLE TUMBLER HI-LIMIT CIRCUIT IS OPEN CYCLE DISPLAY TIME

SPECIFIC HEAT TYPE OR DRYER ELECTRICALLY HEATED FABRIC TEMPERATURE

DEGREE IN FAHRENHEIT

FLASH DISPLAYACTIVE

SPECIFIC HEAT TYPE OF DRYER GAS HEATED INDICATESAN OVERHEAT CONDITION

LINT DRAWER/DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. SWITCH CIRCUIT DRYING CYCLES RANGE FROM 1-10 CYCLES BEFORE CLEAN LINT DISPLAY CYCLE DISPLAY TIME

DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. DOOR SWITCH CIRCUIT MANUAL MODE

MAXIMUM GUARD TIME FLASH DISPLAY NOTACTIVE SAIL SWITCH OPEN

ANTI-WRINKLE PROGRAM IS NOT ACTIVE NO BUZZER (TONE)

GAS ONLY IGNITION ATTEMPT FAILURE NO REVERSE

NO ROTATIONAL SENSOR SELECTED PROGRAM MODE

NO CYCLE IN PROGRESS ROTATIONAL SENSOR SELECTED ROTATIONAL SENSOR CIRCUIT FAILURE

MONITORS TUMBLER RPM WITH ROTATIONAL SENSOR CIRCUIT ACTIVE GAS/ELECTRIC ONLY ATTEMPT MADE TO START DRYER WITH SAIL SWITCH DISABLED IN CLOSED POSITION

SELET REVERSE SPIN TIME

START ANTI WRINKLE GUARD CYCLE

SPECIFIC HEAT TYPE OR DRYER STEAM HEATED STOP TIME

FAULT IN M.P. HEAT SENSING CIRCUIT

48

Page 52
Image 52