If there is voltage present at the two BS1 terminals, the problem is bad wires or terminations between the two BS1 terminals and the coil (A1 and A2) terminals.
If there is no voltage across the two BS1 terminals, check for voltage across the two AS1 termi- nals.
If there is voltage across the two AS1 terminals and there is no voltage between the two BS1 terminals, replace the arc suppressor board.
C.If there is no voltage across the two AS1 terminals, the problem is bad wires or terminations between the two AS1 terminals and the computer board J7
5.Lint Door Condition
NOTE : Make sure main door and lint door are closed. Also, if checking either switch, the plunger must be depressed.
A.Check L.E.D. input light "LINT" on the component side of the computer. If the light is on, replace the computer.
B.Check voltage (24VAC) from J7
C.If no voltage is present at J7
D.If no voltage is present at J7
6. Main Door Condition
NOTE : Make sure main door and lint door are closed. Also, if checking either switch, the plunger must be depressed.
A.Check L.E.D. input light "MAIN" on the component side of the computer. If the light is on, replace the computer.
B.Check voltage (24 VAC) from J7
C.If no voltage is present at J7
7."No Heat" drive and blower motors run, display reads normal (gas models).
A.Check L.E.D. input light "HT1" on the component side of the computer. If the light is on replace the board.
B.If the L.E.D. input light "HT1" on the component side of the computer is on and there is no voltage to the HSI module "w" the display will read "BURNER CONTROL FAIL." The problem is bad wires or terminations between microprocessor and HSI module.
C.If voltage is present on the HSI module "w" to ground. Check voltage at the gas valve if voltage is present across the two yellow wires at the gas valve and the gas supply is on then the fault is that of the gas valve.