0. DRYER SETUP – ALL parameters that pertain to drying are in this menu level.
0.SELECT MODEL – This allows the selection of the heat source applied to the dryer, and whether the dryer is reversing or
GAS REVERSING | GAS |
STEAM REVERSING | STEAM |
ELECTRIC REVERSING | ELECTRIC |
1.SYSTEM TEMP – This selection controls whether the temperature related programs will be operated in Fahrenheit (°F) or Celsius (°C). The programs affected are as follows:
1)Temperature Display Mode
2)Drying Temperatures
3)Cool Down Temperatures
IMPORTANT: The Phase 7
2.ENTER LINT CLEANING FREQUENCY 1 TO 10 HOURS – This selection sets how long the lint cleaning timer will run before prompting the user to “CLEAN LINT”. Once the user is prompted to “CLEAN LINT”, the Phase 7
3.ENTER AUDIO ALERT ON TIMES 0 TO 10 – This selection allows the operator to adjust the amount of signal tones. This parameter (program) affects the tone at the end of the Cool Down Cycle, as well as at the end of the Wrinkle Guard On Time.
4.ROTATION SENSOR – This selection is used to turn the rotational sensor on or off.
5.BOARD ADDRESS 00 TO ZZ – This location is where the board address is defined. This is only used when the Phase 7
6.AUTO CYCLE TIME OUT 0 TO 99 MINUTES – This selection allows the user to set a maximum time that the auto cycle will run before timing out.
12