2: PROGRAM “A-F” CYCLE

SELECT “A-F” KEY

 

*

(“*” DISPLAY THE LETTER CHOSEN. DEFAULTS TO “A”)

SELECT CYCLE TYPE

 

*

(“*” DISPLAY THE CYCLE TYPE “AUTO” or “MANUAL”)

AUTO

0:REVERSE MODE

ON OFF

1:ENTER DRY TEMP 160° F TO 200° F (71° C TO 93° C)

*** F

(“***” = THE DEFAULT DRY TEMP FOR THAT CYCLE)

2: ENTER DRYNESS LEVEL FINISH, DRY, EXTRA DRY

*** %

(“***” = THE DEFAULT DRY LEVEL FOR THAT CYCLE)

3:ENTER CYCLE ADJUSTMENT LEVEL 0 TO 99 (75 = DEFAULT)

4:ENTER CONTROLLED COOL DOWN

(OFF = DEFAULT VALUE)

5:ENTER COOL DOWN TIME 0 TO 90 MINUTES (4 = DEFAULT VALUE)

6:ENTER COOL DOWN TEMPERATURE 70° F TO 100° F (21° C TO 38° C) (80 = DEFAULT VALUE)

MANUAL

0:REVERSE MODE

ON OFF

1:ENTER SPIN TIME 30 TO 120-SECONDS

*** SEC

(60 = THE DEFAULT TIME FOR THAT CYCLE)

ENTER STOP TIME 5 TO 10-SECONDS

*** SEC

(5 = THE DEFAULT TIME FOR THAT CYCLE)

2: ENTER DRY TEMP 100° F TO 200° F (38° C TO 93° C)

*** F

(“***” = THE DEFAULT DRY TEMP FOR THAT CYCLE)

ENTER CONTROLLED COOL DOWN ON OR OFF

(OFF = DEFAULT)

3: ENTER DRY TIME 0 TO 99 MINUTES

** MIN

(0 = THE DEFAULT MINUTES FOR THAT CYCLE)

4: ENTER COOL DOWN TIME 0 TO 99 MINUTES

** MIN

(4 = THE DEFAULT TIME FOR THAT CYCLE)

5: ENTER COOL DOWN TEMP 70° F TO 100° F (21° F TO 38° C)

*** F

(100 = THE DEFAULT TEMP FOR THAT CYCLE)

6:ENTER STEAM INJECTION ON OR OFF (OFF = DEFAULT VALUE)

3:PROGRAM “0-40” CYCLE

1:SEE 2: PROGRAM “A-F” CYCLE

4:DEFAULT SETTINGS

ENTER PASSWORD (PRESS “1” “2” “3”)

CONFIRM DEFAULTS

NO

(DEFAULT VALUE)

YES

 

28

Page 30
Image 30
American Dryer Corp Phase 7.2.2 user manual Auto Reverse Mode On OFF