American Dryer Corp Phase 7.2.2 user manual Man

Models: Phase 7.2.2

1 92
Download 92 pages 10.88 Kb
Page 19
Image 19

NOTE: Press and hold the “DOWN ARROW” to view the basket (tumbler) RPM.

7)Once the preprogrammed percentage of extraction (dryness level) is reached, the drying cycle will end and the Cool Down Cycle will begin.

8)Once the Cool Down Cycle begins at the end of the heat cycle, the light emitting diode (L.E.D.) display will read COOL DOWN TEMP ___/___MINUTES REMAINING. At the end of the heat cycle, the dryer will shut off the heat and continue the fan and basket (tumbler) until the Cool Down Time or temperature is reached.

9)Once the Cool Down Cycle is completed, the Phase 7 non-coin microprocessor controller (computer) will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound (for the amount set in Audio Alert On Time). The L.E.D. display will read “CYCLE DONE”. The dryer will wait an initial 15 minutes delay before going into a 15-seconds ON, 5 minutes OFF cycle. These times are fixed and are not programmable. During the ON Time, the blower (fan) and the basket (tumbler) will start to rotate without heat for 15-seconds; during this time the display will read “WRINKLE GUARD”. After the 15-seconds are completed, the display will read “CYCLE DONE” and the dryer will go into a 5 minute OFF cycle. The Phase 7 non-coin microprocessor controller (computer) will repeat this process of 15-seconds “ON” and 5 minutes “OFF” until either the doors are opened,

the “STOP/CLEAR” key is pressed, or 99 minutes have elapsed, whichever comes first. Once the 99 minutes have elapsed, the L.E.D. display will then read “CYCLE DONE” and will lock out the dryer functions until the doors are opened. The L.E.D. display will then return to “READY”.

b. Timed (Manual) Drying Cycle

1)L.E.D. display reads “READY” (no cycle in progress).

2) Press

MAN

key.

3)L.E.D. display will now read “ENTER DRY TIME 0 TO 99 MINUTES” (defaults to 0). I.E., for

40 minutes, press key “4”, key “0”, and then press the “START/ENTER” key to accept the value.

4)L.E.D. display will now read “ENTER DRY TEMP __ TO __” (defaults to 100° F [38° C]). Enter the temperature desired (from 100° F to 200° F [38° C to 93° C] in one-degree increments). I.E.,

for 182° F (83° C), press key “1”, key “8”, key “2”, and then press the “START/ENTER” key to accept the value.

5)L.E.D. display will now read “ENTER COOL DOWN TIME 0 TO 99 MINUTES”. I.E., for 10 minutes, press key “1”, key “0”, and then press the “START/ENTER” key to accept the value.

6)L.E.D. display will now read “REVERSE MODE” (defaults to ON). The ON/OFF selection can

be toggled with the “UP ARROW” and “DOWN ARROW” . Once selected, press the “START/ENTER” key to accept selection.

17

Page 19
Image 19
American Dryer Corp Phase 7.2.2 user manual Man