A. CYCLE “A-F” PARAMETERS (PROGRAMS) PRESET BY THE FACTORY

CYCLE A:

SELECT CYCLE TYPE =AUTO, 0:REVERSE MODE = ON, 1:ENTER DRYTEMP = 180°F, 2:ENTER DRYNESS LEVEL =

EXTRADRY,3:ENTERCYCLEADJUSTMENTVALUE=70,4:CONTROLLEDCOOLDOWN=OFF,5:ENTERCOOLDOWN TIME = 6 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F

CYCLE B:

SELECTCYCLETYPE=AUTO,0:REVERSEMODE=ON,1:ENTERDRYTEMP=180°F,2:ENTERDRYNESSLEVEL=DRY,

3:ENTER CYCLEADJUSTMENT VALUE = 70, 4:CONTROLLED COOLDOWN = OFF, 5:ENTER COOLDOWN TIME = 6 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F

CYCLE C:

SELECTCYCLETYPE=AUTO,0:REVERSEMODE=ON,1:ENTERDRYTEMP=160°F,2:ENTERDRYNESSLEVEL=DRY,

3:ENTER CYCLEADJUSTMENT VALUE = 70, 4:CONTROLLED COOLDOWN = OFF, 5:ENTER COOLDOWN TIME = 4 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F

CYCLE D:

SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5 SECONDS, 1:ENTER DRYTIME = 40 MINUTES, 2:ENTER DRY TEMP = 190°F, 3:CONTROLLED COOL DOWN = OFF, 4:ENTER COOL DOWN TIME = 6 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF

CYCLE E:

SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5 SECONDS, 1:ENTER DRYTIME = 30 MINUTES, 2:ENTER DRY TEMP = 180°F, 3:CONTROLLED COOL DOWN = OFF, 4:ENTER COOL DOWN TIME = 4 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF

CYCLE F:

SELECT CYCLE TYPE = MANUAL, 0:REVERSE MODE = ON, ENTER SPIN TIME = 60 SECONDS, ENTER STOP TIME = 5 SECONDS, 1:ENTER DRYTIME = 10 MINUTES, 2:ENTER DRY TEMP = 170°F, 3:CONTROLLED COOL DOWN = OFF, 4:ENTER COOL DOWN TIME = 2 MINUTES, 5:ENTER COOL DOWN TEMP = 80°F, 6:STEAM INJECTION = OFF

B. CYCLE “0-40” PARAMETERS (PROGRAMS) PRESET BY THE FACTORY

CYCLE “0-40”:

Manual (Timed) Mode, Reverse, Dry Time = 0, Dry Temp = 100, Cool Down Time = 3 Minutes, Cool Down Temp = 100, Spin Time = 60, Dwell (Stop) Time = 7.