0:SELECT LANGUAGE ENGLISH FRANCAIS ESPANOL ITALIANO DEUTSCH

1:SELECT SYSTEM PARAMETERS

0:DRYER SETUP

0:SELECT MODEL GAS REVERSING ELECTRIC REVERSING STEAM REVERSING

GAS NON-REVERSING

ELECTRIC NON-REVERSING

STEAM NON-REVERSING

1:SYSTEM TEMP DEG F DEG C

2:ENTER LINT CLEANING FREQUENCY 1 TO 10 HOURS

3 (3 = DEFAULT VALUE)

3:ENTER AUDIO ALERT ON TIMES 0 TO 10

5(5 = DEFAULT VALUE)

4:ENTER ROTATION SENSOR ON/OFF (ON = DEFAULT VALUE)

5:BOARD ADDRESS 00 TO ZZ.

6:AUTO CYCLE TIME OUT 0 TO 99 MINUTES 60 (60 = DEFAULT VALUE)

1:REVERSING SETUP

0:ENTER SPIN TIME 30 TO 120 SECONDS

60SEC (60 = DEFAULT VALUE)

1:ENTER STOP TIME 5 TO 10 SECONDS

5SEC (5 = DEFAULT VALUE)

2:WRINKLE GUARD SETUP

0:WRINKLE GUARD AUDIO ALERT

AUDIO ALERT ON

AUDIO ALERT OFF

3:STEAM INJECTION SETUP

0:ENTER ON TIME 10:00 = DEFAULT

1:ENTER OFF TIME

(1-SECOND ABOVE ON TIME – DEFAULT)