N.Temperature Conversion Status Celsius (°C). ALL temperatures changes are made.
–
O. High Temperature Protection – If the Phase 7
C) for radial airflow, it will end the drying cycle and a fault code will be displayed, indicating an overheating problem.
P.Cycle Preview – Entire dryer parameters (programs), or the preprogrammed cycles, are displayed for verification upon a coded entry to the keyboard (touch pad).
Q.Reversing Option – Helps reduce the balling up or tangling of large items. A cycle can be set to have the reversing option, so that the basket (tumbler) will turn in the forward direction for 30- to
R.Rotation Sensor – The Phase 7 key while the basket (tumbler) is on. (The basket [tumbler] must be rotating for approximately
S.Clean Lint – This feature monitors the value of the “Lint Cleaning Frequency” timer. The timer keeps track of how long the dryer’s blower/fan has been on, and compares it to the Lint Cleaning Frequency Setting. Once the timer equals the Lint Cleaning Frequency setting, the Phase 7
T.Language Selection – Phase 7
(5) different languages: English, French, Spanish, Italian, and German.
U.Model Selection – Phase 7
V.Default Factory Settings – This feature will set ALL programmed parameters to their default values.
W.Keyboard (Touch Pad) Symbols –
= “STOP/CLEAR” key
= “START/ENTER” key
= “UP ARROW” key (scroll up)
= “DOWN ARROW” key (scroll down)
X.Steam Injection Option – The Phase 7
5