AMX NXC-M/ME/MPE NXM-MHS Specifications Cont, Program Port DIP switch - baud rate settings

Models: NXC-M/ME/MPE

1 48
Download 48 pages 38.08 Kb
Page 8
Image 8
NXM-MHS Specifications (Cont.)

Product Information - NetLinx Modules

NXM-MHS Specifications (Cont.)

Front Panel Components Cont.):

 

Input LED

Yellow LED blinks when the Master Card receives data from button

 

pushes, strings, commands, channel levels, etc.

Front Panel LEDs -

These LEDs also display special blink patterns when a mode is activated.

blink patterns

See the Modes and front panel LED blink patterns section on page 5 for

 

details.

Program Port DIP Switch

8-position DIP switch located behind the front panel for setting the baud

 

rate for the Program port. The baud rate settings are 9600, 38,400

 

(default), 57,600 and 115,200 (bps). See the Program Port DIP switch -

 

baud rate settings section on page 2 for details.

 

 

Rear Panel Components:

 

PWR connector

2-pin (male) green captive-wire connector for 12 VDC power supply

PROGRAM port

5-pin (male) gray connector for system programming and diagnostics.

 

There is a Program port located on the front and rear of the Master Cards

 

for easy access. Because these ports share the same circuitry, you

 

should never use both ports at the same time. Doing so will result in com-

 

munication and/or programming errors.

ICSNet connectors

Two RJ-45 connectors that provide power (500 mA) and data to external

 

ICSNet devices

ICSNet LEDs

Green LEDs that light when sending/receiving data on that port.

ICSHub In/Out connectors

Two RJ-45 connectors that provide data to other Hubs connected to the

 

Master Card

ICSHub IN/OUT LEDs

Yellow LEDs that light when sending/ receiving data on that port.

AXlink LED

Green LED shows AXlink/NetLink data activity

 

 

Enclosure

Metal with black matte finish

 

 

Front Faceplate

Plastic gray with translucent viewing window

 

 

Dimensions (HWD):

 

Card(s)

1.5" x 5.0" x 8.8" (45 mm x 127 mm x 224 mm)

Module

5.0" x 4.8" x 8.5" (127 mm x 121.9 mm x 215.9 mm)

 

 

Optional accessories

• 12 VDC power supply (PSN 6.5, PSN 2.8)

 

AC-RK Accessory Rack Kit (Module)

 

 

Program Port DIP switch - baud rate settings

The Program Port DIP switch is located at the front of the Master Cards. For Modules, you must remove the front panel to access the DIP Switch.

Use this DIP switch to set the baud rate for the Program Port, according to the settings shown in the following table. Make sure the baud rate you set matches the baud rate on your PC's COM port before programming the Master Card. By default, the baud rate is set to 38,400 (bps). Note the orientation of the DIP Switch and the ON position label.

 

2

NetLinx Master Cards and Modules

 

 

 

Page 8
Image 8
AMX NXC-M/ME/MPE instruction manual NXM-MHS Specifications Cont, Program Port DIP switch - baud rate settings