[6]
1.2 Technical Specifications
Form Factor
1U 19-inch rackmount chassis
RAID processor
Intel XScale IOP331 Instant RAID volume availability and
background initialization support
RAID Level
0, 1, 0+1, 3, 5, 6, 10 and JBOD Supports over 2TB per volume
Cache memory
512MB ~ 1GB DDR333 DIMM supported Online consistency check
No. of channels (host and drives)
2 and 4 Bad block auto-remapping
Host bus interface 1Gb/s Ethernet
S.M.A.R.T. support
Drive bus interface 3Gb/s SATA II
New disk insertion / removal detection
Hot-swap drive trays
Four (4) 1-inch trays Aut o volume rebuild
Host access control
Read-Write & Read-Only Array roaming
Supports CHAP authentication Audible alarm
Jumbo frame support Password protection
Global hot spare disks UPS connection
Maximum logical volume: up to 255 Power supplies: 220W power supply
w/PFC
Maximum host connectionup to 32 Cooling fans1
Maximum host clustering
up to 8 for one logical volume
Power requirements
AC 90V ~ 264V full range
6A ~ 3A, 50Hz ~ 60Hz
Online Volume migration Environmental
Relative Humidity
10% ~ 85% Non-condensing
Online Volume expansion Operating Temp
10oC ~ 40oC (50oF ~ 104oF)
Configurable stripe size Physical Dimensions
44(H) x 446.4(W) x 506(D)mm