4.2 RG Migration

To migrate the RAID level, please follow below procedures.

1.Select “/ Volume configuration / RAID group”.

2.Move the mouse pointer to the gray button next to the RG number; click “Migrate”.

3.Change the RAID level by clicking the down arrow to “RAID 5”. There will be a pup-up which indicates that HDD is not enough to support the new

setting of RAID level, click “” to increase hard drives,

then click ““ to go back to setup page. When doing migration to lower RAID level, such as the original RAID level is RAID 6 and user wants to migrate to RAID 0, system will evaluate whether this operation is safe or not, and appear a message of "Sure to migrate to a lower protection array?” to give user warning.

4.Double check the setting of RAID level and RAID PD slot. If there is no

problem, click “ “.

5.Finally a confirmation page shows the detail of RAID information. If there is

no problem, click ““ to start migration. System also pops up a message of “Warning: power lost during migration may cause damage of data!” to give user warning. When the power is abnormally off during the migration, the data is in high risk.

[73]

Page 73
Image 73
APC iSCSI SATA II installation and configuration manual RG Migration, Select / Volume configuration / RAID group