Notes on Preview Triggers

Preview Triggers can be dragged to a different position at any time.

For Internal Ramps, each new Preview Trigger will affect a reversal in the ramp direction, that is the ramp will bounce back and forth between the two set ramp speeds.

Creating multiple triggers for an Internal Ramp will make the ramp toggle between the first and the second ramp speed.

For External Ramps, each new Preview Trigger will be associated with a ramp point from the Ramp Editor until no more ramp points are left. Any new Preview Triggers will be empty (marked with a “-“) and will have no effect. Please note that the last ramp point in an external ramp has no corresponding preview trigger, as it ends the ramp.

Creating multiple triggers for an External Ramp will create empty triggers if no ramp points are defined in the Ramp Editor.

RPC Operations Guide, Page 16

Page 16
Image 16
ARRI ARRI Ramp Preview Controller manual RPC Operations Guide