5.6 Switching on

master control knob

the HTI lamp

 

Before switching on the HTI lamp, please ensure that

• The Master Control Knob photo is in the ”0” position.

“lamp“-key

• Film is not running in the projector.

1)Depress ”lamp” key for approx. 1 second to ignite the lamp. During this ignition phase, which lasts approx. 5 seconds, all key functions are disabled.

2)The HTI lamp can be switched off after a reset time of 5 seconds by depressing the ”lamp” key again.

Note:

Run-up time to full light power is approx. 40

Note:

The average life of an HTI lamp

 

seconds. Working temperature of the lamp is

 

is approx. 750 hours.

 

reached in three minutes. During this period the

 

Spare lamps can be ordered under

 

lamp should never be switched off, because this

 

Id.No. 05.09873.0.

 

gradually reduces the life of the lamp and

 

 

 

results in poor ignition behavior.

 

 

Initial Operation