60
Fault | Cause | Remedy |
|
|
|
Film channel | Foreign matter in film channel. | Remove obstacle |
“OPEN/CLOSE” function disturbed | Film loop cannot be formed | and actuate “Film” key once again. |
| Film not properly inserted | Tension film slightly on both film plates |
|
| with film channel open. |
|
| Film must drop totally to bottom of film channel. |
| Lamp cover not properly seated | Check film channel slide on lamp cover |
| or distorted | for easy running. If sluggish, replace |
|
| and lock lamp cover with film channel open. |
|
| If this fails, call Service Engineer. |
| Loop sensor dirty; | Clean with ARRI maintenance tools. |
| Reflex light barrier |
|
| on left loop box |
|
| doesn’t detect film loop. |
|
| Electronic board defective | Call ARRI Service station |
|
|
|
Sudden stop during film transport | Film loop monitor switch has detected | Open and close film channel. Repeat film transport. |
| improper splicing or stapled film | In case of stapled film remove staples |
|
| and replace by splicing. |
|
| Then check pressure pad and film guiding elements |
|
| for possible damage. |
|
|
|