Serial Interface (X1)
An ASCII terminal or a personal computer with terminal emulation program can be connected to the serial interface. This makes it possible to check and change the operating parameters.
Some image processing programs allow the integration of control commands which are transmitted to the serial interface.
Connection of PC or terminal via 1:1 connected interface cable (no zero modem cable, no crossed connections).
Setting values
of serial computer interface
Baud rate: ................................ | 9600 Baud/S |
Data format: ............................. | 8 bit, no parity, one start- and one stop bit |
Plug type: ................................. | 25 pin |
Pin configuration: ...................... | see annex ”Interfaces” |
Command Outline
RFX .......................................... |
| Run Forward |
|
|
| ||
|
|
| Function: |
|
|
| |
|
|
| Forward running at selected projection speed. | ||||
Parameters (50 Hz Version) |
|
|
|
|
| ||
X = | 0 | 1 | 2 | 3 | 4 | 5 | 6 |
fps | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0 |
Parameters (60 HzVersion) |
|
|
|
|
| ||
X = | 0 | 1 | 2 | 3 | 4 | 5 | 6 |
fps | 60 | 30 | 15 | 7.5 | 3.75 | 1.87 | 0 |
Note: | This applies only for standard settings (50/50 and 60/60). If these are | ||||||
| changed by “Mode” function (Telecine Mode or Pulldown Mode) then | ||||||
| this frame rate is dominating. See Chapter 6.4.2. |
|
| ||||
RRX .......................................... |
| Run Reverse |
|
|
| ||
|
|
| Function: |
|
|
| |
|
|
| Reverse running at the selected projection |
| |||
|
|
| speed |
|
|
|
|
|
|
| Parameters 50 Hz and 60 Hz version see table | ||||
|
|
| RFX. |
|
|
|
|
Technical Data