Serial Interface (X1)

An ASCII terminal or a personal computer with terminal emulation program can be connected to the serial interface. This makes it possible to check and change the operating parameters.

Some image processing programs allow the integration of control commands which are transmitted to the serial interface.

Connection of PC or terminal via 1:1 connected interface cable (no zero modem cable, no crossed connections).

Setting values

of serial computer interface

Baud rate: ................................

9600 Baud/S

Data format: .............................

8 bit, no parity, one start- and one stop bit

Plug type: .................................

25 pin D-sub socket

Pin configuration: ......................

see annex ”Interfaces”

Command Outline

RFX ..........................................

 

Run Forward

 

 

 

 

 

 

Function:

 

 

 

 

 

 

Forward running at selected projection speed.

Parameters (50 Hz Version)

 

 

 

 

 

X =

0

1

2

3

4

5

6

fps

50

25

12.5

6.25

3.12

1.56

0

Parameters (60 HzVersion)

 

 

 

 

 

X =

0

1

2

3

4

5

6

fps

60

30

15

7.5

3.75

1.87

0

Note:

This applies only for standard settings (50/50 and 60/60). If these are

 

changed by “Mode” function (Telecine Mode or Pulldown Mode) then

 

this frame rate is dominating. See Chapter 6.4.2.

 

 

RRX ..........................................

 

Run Reverse

 

 

 

 

 

 

Function:

 

 

 

 

 

 

Reverse running at the selected projection

 

 

 

 

speed

 

 

 

 

 

 

 

Parameters 50 Hz and 60 Hz version see table

 

 

 

RFX.

 

 

 

 

Technical Data

53