Fault | Cause | Remedy |
|
|
|
Sudden stop during film transport | Loop sensor and reflex protector | Clean with ARRI maintenance tools. |
| on left loop box dirty |
|
| with film dust. |
|
| Emulsion | Remove emulsion |
|
| film track, deflection runner 1 and 2 and from film |
|
| pressure plate, using ARRI maintenance tools. |
|
|
|
Operation too noisy | Improper length of film loop. | Open film channel and slightly tension film loop |
|
| manually by turning the two winding plates. |
|
| Then close film channel. |
|
| If fault still exists, call service engineer. |
|
|
|
Film transport speed malfunctioning | Setting on master control knob | Call ARRI Service station. |
| doesn’t correspond to selected frame rate. |
|
|
|
|
Autostop malfunctioning | Wrong film core. | Use correct film core diameter. |
| Film core diameter must correspond |
|
| to the one selected in |
|
| “Mode” function (Bobby Size). |
|
|
|
|
61