6.9 | Interfaces |
Note: | All interface cables used must comply with CE |
| and EMV guide lines. |
6.9.1 Serial Interface (X1)
Plug type:
Via serial interface (X1) ➪ photo the operational status of the LOCPRO 35 can be checked and changed from a computer.
Chapter 8 ”Serial Interfaces X1” contains listings of technical data as well as listings of computer commands.
Plug – Pin configuration: See Annex ”Interfaces”
6.9.2 Ext Synchro (X2)
Plug type:
Via this interface ➪ photo a signal for shutter synchronization can be supplied externally and the internal shutter signal accessed.
X3 X2 X1
Cine Mode: | ........................................................ | 48 Hz | |
Normal and Telecine Mode: ....................... | 50 or 60 Hz | ||
Shutter revolutions can be changed by ± 3%. |
| ||
Input: .................... | 5 V TTL | ||
Output: ................. | 4 V potential output or | ||
Plug Pin configuration: see annex ”Interface” |
| ||
Note for shutter synchronization: |
| ||
Signal source: |
| ||
External | = | control frequency via X2; top priority! | |
Video | = | when video ”on”. Quartz of video camera. | |
Internal | = | internal quartz generator. |
|