Fault | Cause | Remedy |
|
|
|
Projector does not work with IR | Projector not switched on? | Switch on projector. |
Remote control |
|
|
| Low remote control battery? | Replace battery. |
| Make | |
| is screened off by obstacles in room? |
|
| Battery in remote control is placed in wrong direction | (reversed polarity) Insert battery correctly and try again. |
| Call ARRI Service station. | |
|
|
|
Image runs out of focus | Jet underneath film gate clogged. | Remove foreign matter. |
when switching over from still |
|
|
to motion picture (and | Blower | Call ARRI Service station. |
| Guide vane misadjusted. | Call ARRI Service station. |
|
|
|
Positive film has scratches | Emulsion buildup in film gate. | Clean emulsion deposits from film gate |
on emulsion side in picture area |
| using ARRI plastic scewer. |
| Film gate damaged by stapled film. | Call ARRI Service station. |
|
|
|
Negative film has scratches | Emulsion buildup on pressure pad of film stage | Remove emulsion deposit from pressure pad, |
on emulsion side in picture area |
| using ARRI film track cleaning scewer. |
|
|
|
57