AT&T 7400 series, 7500 series, 7100 series System 75 or Generic 1 G1 to System 85 or Generic 2 G2

Models: 7400 series 2500 series 7200 series 7500 series 7300 series 7100 series

1 348
Download 348 pages 35.19 Kb
Page 130
Image 130

6-12DISTRIBUTED COMMUNICATIONS SYSTEM (DCS)

____________________________________________________________________________________________________________________________

_

System 75 or Generic 1 (G1) to System 85 or Generic 2 (G2)

PI

TN754

(DIGITAL LINE)

TN760

(TIE TRUNK)

TN722

OR TN767

(DS1)

SYSTEM 75/G1

 

 

SIGNALING CHANNEL

 

 

RS449

 

 

RS232C

DCP

 

DSU

MTDM

DSU

 

 

 

RS232C

 

 

TO RS449

 

 

CONVERSION

 

 

ANALOG OR DS1 VOICE CHANNEL

DCIU

SN233

(TIE TRUNK)

ANN11

(DS1)

SYSTEM 85/G2

WITH

TRADITIONAL

MODULE

DCIU

OR

TN760

(TIE TRUNK)

TN722

OR TN767 (DS1)

GENERIC 2

WITH

UNIVERSAL

MODULE

Figure 6-15.Short Haul Analog Signaling: System 75/G1 to System 85/G2 — Direct Via DSU

PI

TN754

(DIGITAL LINE)

TN760

(TIE TRUNK)

TN722

OR TN767

(DS1)

SYSTEM 75/G1

 

 

SIGNALING CHANNEL

 

 

 

 

RS232C

RS449

DCP

MTDM

RS232C

MODEM

 

 

 

MODEM

 

 

 

 

RS232C

 

 

 

TO RS449

 

 

 

CONVERSION

 

 

ANALOG OR DS1 VOICE CHANNEL

 

DCIU

SN233

(TIE TRUNK)

ANN11

(DS1)

SYSTEM 85/G2

WITH

TRADITIONAL

MODULE

DCIU

OR

TN760

(TIE TRUNK)

TN722

OR TN767 (DS1)

GENERIC 2

WITH

UNIVERSAL

MODULE

Figure 6-16.Long Haul Analog Signaling: System 75/G1 to System 85/G2 — Direct Via Modem

Page 130
Image 130
AT&T 7400 series, 7500 series, 7100 series, 2500 series, 7200 series System 75 or Generic 1 G1 to System 85 or Generic 2 G2