C-12TRUNKING TERMS AND CAPABILITIES

____________________________________________________________________________________________________________________________

_

Note: System 75 R1V1 DOES NOT SUPPORT precise dial tone. Therefore, it is recommended that the distant switch be optioned to provide the R1V1 switch with a dc signal (e.g., a wink or delay-dial) as the indication to begin digit sending. System 75 R1V2 (plus all subsequent versions) and all versions of System 85 and Generic 2 DO SUPPORT precise dial tone. However, call completion is faster whenever a dc signal is used. Again, either a wink or delay-dial signal is recommended.

Reverse Battery

A simple method for performing supervision on 1-way DID trunks. The originating end uses open and closure signals, while the terminating end uses battery and ground signals.

Note: Some CO applications (e.g., toll-diversion and answer supervision) may also use reverse battery.

SF (or Single Frequency signaling)

The signaling method where the dc signal states ‘‘on-hook’’ and ‘‘off-hook’’ are converted to ‘‘tone-on’’ and ‘‘tone-off’’ states via special 2600-Hz single frequency interface equipment. This signaling method is not supported by any AT&T PBX. External hardware is required to convert E&M to SF signaling.

Seizure

A switching system action that consists of selecting a trunk circuit for the purpose of completing a call.

Senderized Mode of Operation

Whenever the local PBX collects the address digits before it seizes the trunk and starts sending digits. Depending upon the type call and which trunk routing features are used (e.g., speed calling, subnetwork trunking, extension number steering, AAR, or ARS), either three, four, or all of the dialed digits are collected. Refer to ‘‘Cut-Through Mode of Operation’’ for a contrast.

Note: Certain types of calls operate in the ‘‘Senderized’’ mode of operation. Other types of calls operate as ‘‘Cut-Through’’ mode of operation. Still other types of calls use a combination of both modes.

Signal Converter

Optional equipment, which may be used on analog trunks to convert from one type of signaling to another type of signaling, e.g., ground-start to E&M, ground-start to loop-start, etc.

Signaling (or trunk signaling)

Those control functions (e.g., supervision, alerting, addressing) that are required to establish, maintain, and release a trunk circuit.

Page 252
Image 252
AT&T 7500 series, 7100 series Reverse Battery, SF or Single Frequency signaling, Seizure, Senderized Mode of Operation