SYNCHRONIZATION OF DIGITAL FACILITIES

B-27

_______________________________________________________________________________________

_

 

 

 

 

A

 

 

B

 

C

 

. .

 

 

 

. . . . .

 

 

 

. . . .

 

 

 

. . . . .

 

 

 

. . . . .

 

 

 

. . . .

 

 

 

. . . . .

 

 

 

. . . . .

 

 

 

. . . . . .

 

 

 

. . . . .

 

 

 

. . . .

 

 

 

. . . . .

 

 

 

. . . .

 

 

 

. . . .

 

 

 

. . . . .

 

 

D

E

F

 

 

DIGITAL TRANSMISSION FACILITY

 

 

 

PRIMARY FREQUENCY REFERENCE

 

 

. . . . . . . . . . . . . .

SECONDARY (BACKUP) FREQUENCY REFERENCE

 

 

Figure B-20.Minimized Synchronization from One Node

External-Reference Selection Rules

There are seven rules for selecting external synchronization references. These rules are described next.

RULE 1:

Nodes within the externally referenced sublevel may not use as a reference source a facility from a node within the internally referenced sublevel (refer to figure B-11,External and Internal Reference Levels, for an explanation of these terms).

RULES 2 THROUGH 7:

Rules 2 through 7 are the same for both internal- (that is, SCS, external stratum-3 clock, and HAC) and external-reference selections.