TRUNKING TERMS AND CAPABILITIES

C-17

_______________________________________________________________________________________

_

TRUNKING CHARACTERISTICS TABLE

D ——identifies the DEFAULT supervision option on the Generic 2 for the associated trunk group type and the only option for R2V3 and earlier releases.

-##——identifies a 1- or 2-digit number that corresponds to a particular DIMENSION PBX and/or System 85 signaling type. Beginning with System 85 R2V4, some trunk types may also be optioned (via administration procedures) for signaling types other than the default.

Note: Where appropriate the default designator (D) and the signaling type designator (-##) are combined to identify the default signaling type; for example, the table entry ‘‘D-1’’ means that the default signaling is ‘‘Ground Start.’’ The table entries apply to Generic 2 trunk connections. However, they may also be true for earlier versions of the switch.

Signaling Types:

1 —Ground start

2 —Ground start with party test

3 —Loop/reverse battery, wink start

4 —E&M immed in/immed out

5 —E&M wink-start in/immed-start out

6 —ANI signaling

7 —Auxiliary equipment

8 —E&M delay-dial in/immed-start out

9 —E&M delay-dial in/wink or delay-dial with dial-tone out

10 —E&M wink-start in/wink or delay-dial with dial-tone out

11 —E&M wink-start in/wink or delay-dial out (universal sequence)

12 —E&M immed in/wink or delay-dial out

13 —E&M release link trunk out

14 —E&M release link trunk in

15 —E&M main satellite immed start

16 —E&M main satellite wink start

17 —E&M main satellite delay-dial out

18 —S-channel signaling, host access GPP, host access EIA

19 —Loop start

20 —DMI ISDN-MOS

21 —E&M wink-start in/wink-start out

22 —E&M delay-dial in/delay-dial out

23 —E&M delay-dial in/wink or delay-dial out

24 —E&M delay-dial in/wink or delay-dial out

25 —E&M immed-start in/wink or delay-dial out with fail on timeout

26 —E&M wink-start in/wink or delay-dial out with fail on timeout

27 —Analog line loop

28 —E&M automatic in/immed-start out

29 —E&M automatic in/wink-start out

30 —Loop/reverse battery, immed-start

31 —E&M immed-start in/automatic out

32 —E&M automatic in/automatic out