Red alarm means that two out of four (or worse) framing patterns were received.

Slip rate of selected DS1 facilities (with respect to the primary reference) exceeds a given threshold

Misframes at the primary reference exceed a given threshold

Reception of a yellow alarm (or a blue alarm for R2V4, 1.1 and later)

Health of SCS circuit pack

Insane condition of the board processor on a DS1 circuit

Table B-1,SCS References Switches, summarizes these conditions:

 

 

 

 

Table B-1.SCS References Switches

 

 

 

 

 

_________________________________________________________________

 

Primary

⎜⎜

 

 

 

Secondary Reference Indicators

 

 

 

⎜⎜

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference

______________________________________________________

⎜⎜

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

⎜⎜

RED

 

 

YEL

GOOD

LOS

MISF

BO

Indicators

⎜⎜

BLUE

_________________________________________________________________

 

⎜⎜

 

 

 

 

 

 

 

 

RED

⎜⎜

HAC

HAC

SEC

SEC

HAC

SEC

HAC

_

⎜⎜

BLUE

 

 

 

 

 

 

 

 

⎜⎜ HAC

HAC

SEC

SEC

HAC

SEC

HAC

YEL

⎜⎜

PRI

PRI

PRI

SEC

PRI

PRI

PRI

_

 

 

GOOD

⎜⎜

PRI

PRI

PRI

PRI

PRI

PRI

PRI

⎜⎜

LOS

⎜⎜ HAC

HAC

SEC

SEC

HAC

SEC

HAC

MISF

⎜⎜

PRI

PRI

SEC

SEC

PRI

PRI

PRI

_

⎜⎜

BO

 

 

 

 

 

 

 

 

⎜⎜ HAC

HAC

SEC

SEC

HAC

SEC

HAC

 

 

 

 

BLUE

Blue alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

Red alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

Yellow alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

LOS

 

Loss of signal

 

 

 

 

 

 

 

 

 

 

 

 

 

HAC System 85’s internal high-accuracy clock

 

 

 

 

 

 

 

 

 

BO

 

Maintenance busied out

 

 

 

 

 

 

 

 

 

 

 

MISF

Misframe

 

 

 

 

 

 

 

 

 

 

 

 

 

GOOD

No alarms

 

 

 

 

 

 

 

 

 

The SCS circuit pack’s health is examined when the system clock’s health is evaluated. Error conditions of varying severity can exist on the SCS. If the fault is minor and the SCS can still lock on the current DS1 reference, a low-priority request for a soft switch to the offline side is made after an unsuccessful attempt to clear up the error condition on the SCS. If the SCS cannot lock onto the current DS1 reference clock, a high-priority request for a soft switch is made. The offline SCS is also monitored to make sure that a switch is not attempted to an unhealthy SCS. If the SCS is not duplicated and the HAC is healthy, serious failures cause a switch to the HAC to ensure switch reliability. When the SCS can once more lock onto a DS1 reference, a switch to that reference is performed.

Synchronization occurs at several priority levels; records are kept for perusal at the demand test level with procedure 625. In addition, several yellow LEDs on the SCS can be observed to get a current picture of how the system is configured from a reference clock point of view.

The LED in position #4 refers to the primary DS1 reference. The LED is OFF if a synchronization signal is present and the SCS is capable of locking. The #4 LED is ON if an error condition exists and the synchronization cable is present.