AT&T 7400 series, 7500 series, 7100 series manual Figure B-16.Less Than Optimal Diverse Routing

Models: 7400 series 2500 series 7200 series 7500 series 7300 series 7100 series

1 348
Download 348 pages 35.19 Kb
Page 232
Image 232

B-24SYNCHRONIZATION OF DIGITAL FACILITIES

____________________________________________________________________________________________________________________________

_

A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D

B

C

DIGITAL TRANSMISSION FACILITY

PRIMARY FREQUENCY REFERENCE

. . . . . . . . . . . . . . . . . SECONDARY (BACKUP) FREQUENCY REFERENCE

Figure B-16.Less Than Optimal Diverse Routing

RULE 5:

Obtaining both primary and secondary synchronization facilities from within the same transmission cable should be minimized.

RULE 6:

The total number of cascade node connections from the referenced node should be minimized.

EXAMPLE FOR RULE 6

Figure B-17,Excessive Cascading, shows excessive cascading in that node B derives timing from a source three transmission facilities away.

Figure B-18,Minimized Cascading, shows less cascading in that node B derives timing from a source two transmission facilities away. Excessive cascading is undesirable because of intermediate link vulnerability. For example, an intermediate link failure in node C of figure B-17,Excessive Cascading, would cause node B to lose timing. Such a failure increases the number of slips between nodes A and B. However, the same failure in Node C of figure B-18,Minimized Cascading, does not affect node B’s synchronization.