Workaround: Use the following table to determine the option that corresponds to the rate that you want to set.

Table 8. Flood Rate Limiting on 80-Series 10/100 Modules

Desired Rate

Web or CLI Setting

 

 

80%

10%

 

 

40%

5%

 

 

20%

2%

 

 

10%

1%

 

 

*Note: Do not use the 20%, 40%, or 80% options of the Web Agent or CLI.

Frames Transmitted with Cyclic Redundancy Check (CRC) Errors

Problem:For certain revisions of the Cajun P550R/P580/P880/P882 switch 12- and 20-port module (Model M5520-100TX, module Type 9, revision level A or B and M5512-100TX, Revision A), a temperature sensitivity problem has been found when operating at 10 Mbps. This sensitivity results in the port transmitting frames with CRC errors. These frames, since they have CRC errors, are then dropped by the receiving station.

Workaround: The following legacy-clicommand allows you to implement a new configuration to disable the power saving mode of the Phy chip. This has the same effect as moving the port’s operational temperature past the problem range. The new configuration is saved only in

NVRAM:

>port set DisablePowerSave <port> on

*Note: Except for this command, the Legacy-CLI is not supported by the Cajun Switch.

610-0184-095

June 14, 2001

19

Page 19
Image 19
Avaya P550R, P580, P880 manual Frames Transmitted with Cyclic Redundancy Check CRC Errors, Desired Rate Web or CLI Setting