Known Problems and Workarounds
The following known problems and workarounds apply to Cajun P550R, P580, P880, and P882 switches that are running switch software, v5.2.2. If a known problem has a viable workaround, it immediately follows the Problem statement. If the known problem has no viable workaround, it is listed as a bulleted statement.
ARP
Problem:50-Series and
Workaround: Reboot the switch twice after performing an NVRAM init.
ATM Uplink Modules
The following problem has no workaround:
■The
Command Line Interface (CLI)
The following problem has no workaround
■The “!” character, when used as part of a CLI command, is considered a comment by the Cajun switch software:
—If you type “!” BEFORE a CLI command, the switch ignores the command and returns you to the CLI prompt.
—If you type “!” after a CLI command, the switch displays an Invalid Command or Syntax Error error message.
Flood Rate Limiting
Problem:The options for setting flood rate limiting on
18 | June 14, 2001 |