6.RS-232 & RS-485 Protocol

6.1Setup

6.1.1Use a Null Modem cable (the standard RS-232 9 Pin Cable with Pin 2 and Pin 3 exchanged, see pin configuration chart below for details) to connect the COM 1 on the rear panel of the DVR to a PC.

6.1.2Set the RS-232option to ON in the COMMUNICATION page of the setup menu.

6.1.3Set the PC communication parameters: 9600 bps, No Parity, 8 Data Bits, 1 Stop Bit.

6.2Communication Protocol

6.2.0General Command Format

<Lead Code = 0x41>, < Dest ID >, < Src ID >, <Main category >, <Second category >, {<Number of parameters>, <Parameter 1>, <Parameter 2> ..,} <End Code= 0x4f>

Lead Code

= 0x41

Dest ID

= 0x01

Src ID

= 0x20

Main Category = 0x01 Keys and Signals

=0x02 Command

Second Category = 0x01 Handshake

=0x02 Request Time/Set Time

=0x06 Request System State

=0x0b Time Search

=0x10 Request HDD Info

=0x11 Request REC Position

=0x12 Playback Immediately

End Code= 0x4f

The different command types and their corresponding parameters are as follows:

6.2.1Keys and signals

PC Send: <0x41>, <0x01>, <0x20>, <0x01>, <Key Value>, <0x4f>