46CCM Installer/User Guide
In the following example, the keyword parameter “baud” is misspelled. Even if more than three characters are entered, they must all be correct.
>port 2 Set Baux=57600 flow=xon
ERR 26 - SET keyword parameter invalid
In the following example, the keyword value “576” is not valid. Numeric keyword values must be fully specified and may not be shortened to three characters.
>POR 2 SET BAUD=576 FLOW=XON
ERR 27 - SET keyword value invalid
In the following example, there are spaces between BAUD, the equal sign and the value 57600. Spaces are not permitted between keyword parameters and their values.
>POR 2 SET BAUD = 57600 FLOW=XON
ERR 26 - SET keyword parameter invalid
Command displaysFor commands that display information, if the information spans more than one screen,
Press the Spacebar to see the next screen.
Enter
Enter q to quit.
Syntax conventionsThis manual uses the following command syntax conventions:
•Brackets [ ] surround optional keywords and values.
•Angle brackets < > surround
•In most cases, choices are separated by a vertical bar . The description indicates if you may specify more than one of the choices and how to separate multiple values. The exception is the Server SSH command. In this case, the vertical bar is specified on the command line when you wish to enable the “password or key” method (PWKEY) or the “key or password” method (KEYPW).