Chapter 5: CCM Appliance Commands

71

 

 

Methods on page 30, Enabling plain text Telnet and SSH connections on page 23 and Using security lock-outon page 32.

When you enter this command, you are prompted to confirm or cancel the specified information.

Access right: SCON

Access level: APPLIANCEADMIN

Syntax

SERVER SECURITY [AUTHENTICATION=<auth>] [ENCRYPT=<conns>] [LOCKOUT=<hours>]

Table 5.19: Server Security Command Parameters

Parameter

Description

 

 

 

 

Authentication method. You may specify multiple values (other than None),

 

separated by commas. Valid values are:

 

LOCAL

Use the local CCM user database to authenticate users.

AUTHENTICATION=

RADIUS

Use the previously defined RADIUS server(s) to authenticate users.

<auth>

NONE

Do not authenticate users. This method cannot be used when SSH

 

 

access is enabled, and it cannot be combined with other

 

 

authentication methods.

 

Default = LOCAL

 

 

 

Enables/disables plain text Telnet or SSH connections. You may enable both by

ENCRYPT=<conns>

specifying both values, separated by a comma. Valid values are:

SSH

Enables SSH connections.

 

None

Enables plain text Telnet connections.

 

Default = None

 

 

 

LOCKOUT=<hours>

Enables or disables security lock-out. To enable, specify the number of hours in the

lock-out period, in the range 1-999. To disable, specify a zero value.

 

Default = 0 (disabled)

 

 

 

Server Set command

The Server Set command changes CCM appliance address settings. You may specify one, two or all three parameters. A reboot is required if you change the IP address.

Access right: SCON

Access level: APPLIANCEADMIN

Syntax

SERVER SET [IP=<ip_address>] [MASK=<subnet>] [GATEWAY=<gtwy>]

Table 5.20: Server Set Command Parameters

ParameterDescription

IP=<ip_address>

IP address.