4.2.2 Operation using separate drive and logic supplies

For improved noise immunity, the ±12V and +5V supplies used for the control card and internal circuitry can be derived from a separate logic supply. To operate the NextMove ST using separate drive and logic supplies, do not link power input connector pins. Connect power as shown in Figure 3.

Rectifier

(logic)

Fuse

Rectifier

(drive)

Fuse

POWER IN 5

4

3

2

1

PSU Logic: 12-35 VDC or 12-30 VAC

PSU Drive:

12-35 VDC or

12-30 VAC

Figure 3 - Connecting separate drive and logic supplies

4-4 Input / Output

MN1921

Page 18
Image 18
Baldor iMN1921 Operation using separate drive and logic supplies, Connecting separate drive and logic supplies