7-6 Keypad Operation MN792

Menu Shortcuts and Special Key Combinations

Quick Tag Information

In any menu system, when a parameter is displayed hold down the M key for approximately 1/2 second to
display the tag number for that parameter. In section 3, the example was given as shown in Figure 7-4. Each
parameter has a tag number associated with it. For example, the Output of Analog Input 1 has a tag number of
[246]. The value of tag [246] is 100. Input 1 parameter of Setpoint Sum 1 has a tag number of [100].

Figure 7-4 Menu Map

Analog Input 1
Output [246]
[230] Calibration
[231] MAX Value
[232] MIN Value
ANIN 1 (A2) [50]
1.0000
100
0.00V
Setpoint Sum 1
SPT Sum [86][6] Ratio 1
[208] Ratio 0
1.0000
1.0000
[419] Divider 1
[420] Divider 0
[131] Deadband
1.0000
1.0000
[292] Sign 0
Positive
Positive
[8] Sign 1
[375] Limit
[423] Input 2
[100] Input 1
105.00%
[309] Input 00.00%
0.00%
0.00%
Restore Factory Settings (2 Button Reset)
Powerup the drive holding two keys as described in Figure 7-5. The drive is now safely configured with the
factory settings described later in this manual (for the existing product code).
The factory settings are not automatically saved to nonvolatile memory, so you must perform a Parameter
Save to save the settings. Figure 7-5 2 Button Reset

INITIALIZING

FACTORY DEFAULTS

DC 2Q 15A

ts
With power off, press and hold the UP
and DOWN arrow keys.
Apply power to the control and continue
to hold both keys for at least 2 seconds.

BALDOR DC DRIVE