5-2 Switch Setting & Start-Up MN792
Power up in Local Mode with Armature Feedback Continued
3. Set the parameter Configure Enable to Enabled.
Action Description Display Comments
Apply Logic Power Keypad Display shows this opening
message. FORWARD
REF: 0.00%
LEDs are flashing. After several
seconds the next screen is displayed.
Press PROG key BALDOR DC DRIVE
DC 4Q 35A
Press M key DC 4Q 35A
MENU LEVEL
Press M key Access the menus. MENU LEVEL
DIAGNOSTICS
Press Scroll to Configure Drive menu. MENU LEVEL
CONFIGURE DRIVE
Press M key Access Configure Drive menu. CONFIGURE DRIVE
CONFIGURE ENABLE
Press M key Access the Configure Enable
parameter. CONFIGURE ENABLE
DISABLED
Press Enable Configure Enable. CONFIGURE ENABLE
ENABLED
All LEDs are now flashing.
Press E when done.
Press E key Returns to previous menu level. CONFIGURE DRIVE
CONFIGURE ENABLE
4. Set the Nominal Motor Volts (Armature Voltage) in the Configure Drive menu.
Action Description Display Comments
Press Scroll to the NOM Motor volts
parameter. CONFIGURE DRIVE
CONFIGURE ENABLE
Press M key Access the NOM Motor Volts
parameter CONFIGURE DRIVE
NOM MOTOR VOLTS
Press PROG key NOM MOTOR VOLTS
180 VOLTS
Press to change to current control if
desired. Press E when done.
5. Set the Armature Current. Note the maximum armature current from the motor name plate and set
this value in the Armature Current parameter.
Action Description Display Comments
Press Scroll to the Armature Current
parameter. CONFIGURE DRIVE
CONFIGURE ENABLE
Press M key Access the Armature Current
parameter CONFIGURE DRIVE
ARMATURE CURRENT
Press PROG key ARMATURE CURRENT
11.5 AMPS
Press to change to current control if
desired. Press E when done. Max
value is hardware limited.
Note: Holding the M key scrolls the
cursor the left most digit so it can be
changed more quickly.