Random Access Adjustment Mode
How to find the correct values for the displayed item?
During the installation of a file with LOAD, the horizontal period, the total number of vertical lines and the interlaced mode are automatically measured and filled in in the menu table. These values will be available when starting up the EDIT procedure of an active file.
Caution : Do not adjust these settings on an active file, they are used to identify the input source file.
If the value for "Horizontal Total Pixels" is wrong, sampling mistakes (small vertical bars in the projected image) will be seen in the image. Select "Total" and adjust the pixel quantity. Adjust for zero bars (hint: if the number of bars increase, adjust in the other direction).
The "Active Pixels" : determine the width of the window on the screen. This value is normally given in the source specifications. If not, adjust until full image is displayed (no missing pixels).
"Horizontal Start" : number of pixels between the beginning of the input signal and the start of the video information in the signal.
"Horizontal Period" : already filled in with the correct value when active file. (see caution above).
The "Vertical Total Lines" are already filled when an active file is selected to be edited (see caution above).
The "Active Lines" : number of horizontal lines determining the height of the projected image. This value is normally given in the specification of the source. If not, adjust until full image height is displayed (no missing lines)
Vertical start : number of lines between the start of the input signal and start of the image on the screen.
Interlaced [On] or [Off] : this selection is automatically filled when active file has to be edited. If the image is wrong due to mismeasurement, use the ENTER key to toggle between [On] and [Off]. (for interlaced images, 1 frame contains 2 fields).
Read AMDS
AMDS = automatic mode detection & synchronisation
During the installation of a file with LOAD, the system automatically measured the horizontal period, the total vertical lines and the interlaced mode.
When selecting Read AMDS, the system remeasures the above indicated items.
Options
| EDIT FILE OPTIONS | |
Source number | 1 | |
Clamp position | [leading] | |
Clamp delay | 0 | |
Clamp width | 10 | |
Field | polarity | [pos] |
Field | select | [both] |
Vertical refresh | [sync] | |
Vert. sync polarity | [leading] |
Select with or <ENTER> to toggle
or to change value <EXIT> to return
Source Number : The source number of a
Clamp Position : Clamping determines the black level of the signal.
The clamp pulse can be related to the leading or the trailing edge of the sync pulse. Use the ENTER key to toggle between [leading] and [trailing].
Clamp Delay : The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be any value between 0 and 255. Change the value by pushing the cursor key or .
Clamp Width : The width of the clamp pulse
Can be any value between 0 and 255. Change the value by pushing the cursor key or .
xample for clamp position [trailing]
leading edge | trailing edge |
Sync pulse
Clamp pulse
Clamp
width
Clamp delay
5976072 BARCOELM R12 17012000 |
| |
|