Service Mode

Setting up the Baud rate

To change the baud rate, handle as follow :

1Push the cursor key or to highlight 'Baudrate' (menu 1).

The actual baud rate will be displayed.

2Press ENTER to toggle between the available baudrates. Default : 9600

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [115200]

INTERFACE STANDARD [RS232]

RS422 TERMINATION [ON]

Select with or

then <ENTER>

<EXIT> to return.

menu1

Available Baud rates

115200/57600/38400/19200/9600/4800/1200

Installing the Interface Standard

The communication protocol for the communication between the projector and a computer can be set on RS232 or RS422. To set up the desired protocol, handle as follow :

1Push the cursor key or to highlight 'Interface Standard' (menu 1). The actual interface standard will be displayed.

2Press ENTER to toggle between RS232 and RS422. Default : RS232

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [115200]

INTERFACE STANDARD [RS232]

RS422 TERMINATION [ON]

Select with or

then <ENTER>

<EXIT> to return.

menu1

RS422 Termination

The last projector in a line should be RS422 terminated (ON position). All others in the line should be in the OFF position. To change the termination position :

1Push the cursor key or to highlight 'RS422 Termination' (menu 1). The actual setting will be displayed.

2Press ENTER to toggle between ON and OFF. Default setting : ON

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [115200]

INTERFACE STANDARD [RS232]

RS422 TERMINATION [ON]

Select with or

then <ENTER> <EXIT> to return.