Divar Installation Manual Hardware setup
EN
Monitor connections
Connect the unit to the monitors using
If the monitor has a
Specifications
Output signal: | Composite video 1Vpp, 75 Ohm, Sync. 0.3Vpp ±10% |
Resolution: | 720 x 576 PAL, 720 X 484 NTSC |
Connector type: | BNC |
Console port connection
The serial RS232 console port connector is used to connect a PC to the unit for configuration or service purposes. Use a
The serial RS232 console port connector is also used to connect Bosch D9000 series control panels via an interface unit for Divar alarm activation. Alarm input mapping can be set up in the menu system.
Specification
Connector type: | |
Maximum input voltage: | ±25V |
Communicaton protocol: | Output signals according |
RS232 console port socket
Signal Name: | Pin no. | Description |
|
DCD_in | 1 | Carrier detection signal (not used). | |
|
|
| |
RX | 2 | RS232 receive signal | |
|
|
| |
TX | 3 | RS232 transmit signal | |
|
|
|
|
N/C | 4 | No Connection |
|
|
|
|
|
System Ground | 5 | System Ground |
|
|
|
|
|
N/C | 6 | No Connection |
|
|
|
| |
RTS | 7 | RS232 request to send signal | |
|
|
| |
CTS | 8 | RS232 clear to send signal | |
|
|
|
|
N/C | 9 | No Connection |
|
|
|
|
|
|
|
|
|
|
| 5 | 1 |
|
| 9 | 6 |
Panel view
Bosch Security Systems