Divar Installation Manual Hardware setup
EN
Control port
The control port is a
8 |
| 1 |
|
15 |
| 9 |
|
|
| SHIELD |
|
| + | CTRL 1 |
|
| - |
| |
|
|
| |
|
| SHIELD |
|
| + | CTRL 2 |
|
| - |
| |
|
|
| |
| + | SHIELD |
|
| CTRL 3 |
| |
| - |
| |
|
|
| |
| + | SHIELD |
|
| CTRL 4 |
| |
| - |
| |
|
|
| |
| + | SHIELD |
|
| CTRL 5 |
| |
| - |
| |
|
|
| |
|
| SHIELD | Panel view |
Specifications
Output impedence: | 128 Ohm |
Overvoltage protection: | ±30V max. |
Differential voltage amplitude:1V min, 2V max. with a characteristic load of 220 Ohms connected across the differential output
Cable length: | 1.5 Kilometers max. |
Recommended cable: | Belden 8760 |
Number of loads per output: | 4 max. |
Control port - 15-pole D-type socket
Signal name: | Pin no. | Description |
Code 1 - | 1 | |
|
|
|
Code 1 + | 2 | |
|
|
|
Shield | 3 | System ground/cable shield. |
|
|
|
Code 2 - | 4 | |
|
|
|
Code 2 + | 5 | |
|
|
|
Shield | 6 | System ground/cable shield. |
|
|
|
Code 3 - | 7 | |
|
|
|
Code 3 + | 8 | |
|
|
|
Shield | 9 | System ground/cable shield. |
|
|
|
Code 4 - | 10 | |
|
|
|
Code 4 + | 11 | |
|
|
|
Shield | 12 | System ground/cable shield. |
|
|
|
Code 5 - | 13 | |
|
|
|
Code 5 + | 14 | |
|
|
|
Shield | 15 | System ground/cable shield. |
|
|
|
Bosch Security Systems