Divar Installation Manual Menu system
EN
>>>Output handling
•Select the profile for which you wish to configure the output handling.
•Select the number of the output relays to be activated when an enabled event in the selected profile is activated.
•Enable the beeper to activate it when an enabled event in the selected profile is activated.
>>>Recording setup
•Recording behavior for each of the six profiles is specified in three submenus. The Normal submenu is for a normal situation without alarms or motion events. The Input submenu is for input changes. The Motion submenu is for motion events.
•The list gives an overview of inputs and motions that are used in any of the profiles. A check mark means used.
Normal
•Select the profile. The Unallocated IPS item shows the IPS capacity remaining.
•A total of 60 images per second (IPS) can be recorded for NTSC; 50 IPS for PAL. A minimum of 1 IPS is always allocated per camera for
•Set the recording rates and quality levels for each camera. Quality is standard, medium or high.
•IPS rates for PAL range from Never, 0, 1/10 (one image every 10 seconds), up to 25 IPS.
•IPS rates for NTSC range from Never, 0, 1/10 (one image every 10 seconds), up to 30 IPS.
•Set the recording speed to NEVER to not record a camera at all. No
Input
•Each input, when activated, can change the normal recording behavior of up to four cameras for a maximum of 120 seconds.
•Select the profile. Select the input number.
•Select the cameras whose recording behavior should change. Set the recording rates and quality levels for each camera. Set camera name to None to use less than four cameras.
•To free IPS bandwidth, the recording rate of cameras not in alarm is limited to the IPS number displayed.
Motion
•Each motion input, when activated, can change the normal recording behavior of up to four cameras for a maximum of 120 seconds.
•Select the profile. Select the motion camera number.
•Select the cameras whose recording behavior should change. Set the recording rates and quality levels for each camera. Set camera name to None to use less than four cameras.
•To free IPS bandwidth, the recording rate of cameras not in alarm is limited to the IPS number displayed.
>>>Access restrictions
•Remote access restrictions can be set for each of the six profiles.
•Select the profile. Select if local playback is enabled or not.
•Select which remote users have access and which are blocked.
•Remote user 1, the administrator, always has access.
>>>Copy system behavior
•To copy the settings of one profile to another, enter the number of the source profile, enter the number of the destination profile and select the Copy Now item.
Bosch Security Systems