Bosch Appliances Divar -Digital Versatile Recorder External I/O connection, Connecting the Inputs

Models: Divar -Digital Versatile Recorder

1 80
Download 80 pages 47.21 Kb
Page 39
Image 39

Divar Installation Manual Hardware setup

EN 4-7

External I/O connection

Alarm inputs and outputs are supplied via a 25-pole D-type socket. The screw terminal input/output connection board supplied with the unit simplifies all alarm connections to the unit.

13

1

25

14

Connecting the Inputs

Each (alarm) input line can be switched by a relay contact from devices such as pressure pads, passive infra-red detectors, smoke detectors and similar devices. Wire them as either N/O or N/C. You can configure the alarm inputs as N/O or N/C in the menu system. The default is N/O.

Connecting the Alarm Outputs

The four alarm output relays respond to input alarms and triggers. You can configure the alarm outputs as N/O or N/C in the menu system. The relays are active for the duration of the driving event. Connect the application to the alarm output relays (resistive loads only). Do not exceed 30 Vac, 40Vdc, 500 mA (continuous) or 10VA on an alarm output relay's contacts. The contacts must not be used at AC line voltages.

Specifications

1A

R

 

3A

 

E

 

 

1B

 

3B

 

L

 

 

2A

 

4A

 

A

 

 

2B

Y

 

4B

 

 

 

GND

 

 

 

 

 

 

 

1

 

 

IN

9

 

2

 

 

10

 

 

 

GND

 

 

 

 

 

 

Alarm input impedence: Input voltage range: Input voltage treshold:

Switching current (resistive): Carrying power:

Switching voltage (resistive):

Internal pull-up 10K to +5V -0.3V min to 30V max Low voltage 0.8V max High voltage 2.4V min 500mA max

10VA max

30 Vac / 40 Vdc max

3

 

IN

11

4

 

 

12

 

 

GND

 

 

 

 

 

5

 

IN

13

6

 

14

 

 

 

 

GND

 

 

 

 

7

 

IN

15

8

 

 

16

Panel view

External I/O - 25-pole D-type socket

Signal name:

Pin no.

Description

Alarm_in_1

1

Alarm input 1

 

 

 

Alarm_in_2

2

Alarm input 2

 

 

 

Alarm_in_3

3

Alarm input 3

 

 

 

Alarm_in_4

4

Alarm input 4

 

 

 

Alarm_in_5

5

Alarm input 5

 

 

 

Bosch Security Systems