62 | en Basic configuration tasks | Bosch Video | |
Management System | |||
|
| ||
|
|
|
3.In the Log - Schedule column, click a cell and select the appropriate schedule.
The schedule determines when the event is logged.
4.In the Script - Script column, click a cell and select an appropriate Command Script.
5.In the Script - Schedule column, click a cell and select the appropriate schedule.
The schedule determines when the event triggers the start of the Command Script.
4.8Configuring an alarm
Main window > Alarms
Before configuring an alarm you must configure the trigger in Events.
To configure an alarm:
1.In the tree, select an alarm, for example System Devices > Authentication > Operator Authentication Rejected.
The corresponding Alarm Configuration Table is displayed.
2.In the Priority column, click ... in a cell to type the alarm priority for the selected alarm (100 is low priority, 1 is high priority).
In the Title column, click ... in a cell to type the title of the alarm to be displayed in Bosch Video Management System, for example in the Alarm List.
In the Color column, click ... in a cell to display a dialog box for selecting a color for the alarm to be displayed in the Operator Client, for example in the Alarm List.
3.In the
Make the required settings.
2012.07 V1 F.01U.269.054 | Quick Start Manual | Bosch Sicherheitssysteme GmbH |