| MIC400 Series Camera Installation and Operation Manual |
| EN 22 | ||||||||
|
| There are 5 fuses fitted to the power supply. All are 20mm fuses. With the | FIGURE D – | |||||||||
|
| following functions: |
|
|
|
|
|
|
|
| ||
|
| Table I – Fuse Ratings for |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fuse |
| Function |
| Type |
| Rating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| FS1 |
| 15v AC secondary fuse. |
| Glass |
| 1.6A quick blow |
|
|
|
|
|
|
|
| Mic supply. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| FS2 |
| Mains input fuse for |
| Ceramic |
| 600mA Quick |
|
|
|
|
|
|
|
| transformer. |
|
|
| Blow |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| FS3 |
| IR Lamp supply fuse. |
| Glass |
| 2.5A Quick |
|
|
|
|
|
|
|
|
|
|
|
| blow. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| FS4 |
| Mains fuse for Washer |
| Ceramic |
| 2Amp Quick |
|
|
|
|
|
|
|
| drive. |
|
|
| Blow. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| FS5 |
| 15v AC secondary fuse. |
| Glass |
| 1.6A Quick |
|
|
|
|
|
|
|
| MIC supply. |
|
|
| Blow. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WARNING: Fitting fuses other than the values described above invalidates the product warranty and may result in damage to the product or injury to the installer.
WARNING:
This ident is in error and the correct value is 2.5Amps.
Power Supply Layout and Connections
HD1 - Power Input connector (screw terminal)
HD2 - Alarm Input header (screw terminal)
HD3 - Composite cable header (Connections to camera head, screw terminal)
HD4 - Telemetry header (Molex Connection)
HD5 - Telemetry header (screw terminal)
HD6 - IR Lamp header (screw terminal)
HD7 - Washer drive power input header (screw terminal)
CN1 - Coax Video Header (BNC Connector)
SK1 - Washer pump drive header (screw terminal)
Bosch Security Systems | Issue 1 |