MIC400 Series Camera Installation and Operation Manual
Table F – Fuse Ratings for
EN 17
Fuse ident
FS 1
FS 2
FS 3
FS 5
Fuse function.
MIC400 protection
Primary protection.
Heater protection 1
Heater protection 2
Rating for 240v
primary
1.6A glass Anti
surge (T)
200mA ceramic
quick blow
1.6A glass Anti
surge (T)
1.6A glass Anti
surge (T)
Rating for 115v
primary
1.6A glass Anti
surge (T)
500mA ceramic
quick blow
1.6A glass Anti
surge (T)
1.6A glass Anti
surge (T)
7. | CN2 is for additional add on cards such as alarm inputs, video processors, |
|
|
8. | Telemetry connections are provided by headers HD3, HD4 and HD5 which |
| respectively enable crimp or screw terminations for connecting the MIC400 |
| to the control room as per Table D. |
9. | Connect the power to HD1 carefully observing the polarity and voltage as |
| per Table B. |
10. | When wiring is complete, apply power & check the all four (4) LED’s are lit. |
Installation Instructions
WARNING: Electrical Danger: Ensure all power is disconnected before opening or working upon any Power Supply Unit.
Installation must be carried out by suitably qualified persons
&all local safety regulations should be followed.
1.Locate the mounting position of the
2.Securely fix the
3.Feed all cabling through the appropriate sized gland holes.
4.Connect the composite cable to HD3 following the colour coding as shown in the Table C & printed on the PCB.
5.If a tamper switch relay is to be used, connect this at HD2.
6.Connect the Coaxial video cable to the CN1 header.
11. | Following Installation when power is applied the following LEDs will light to |
| indicate:- |
| LED1 – 15vAC power on to camera |
| LED2 – 15vAC power on camera |
| LED4 – Power on for optional heater/speaker |
| LED5 – Power on for optional heater/speaker |
12. | |
13. | For installation of the |
| please refer to their respective manuals. |
Bosch Security Systems | Issue 1 |