MIC400 Series Camera Installation and Operation Manual

 

EN 23

Table J - Alarm Input header for MIC-IR Power Supplies HD2

Installation Instructions

Connection

HD2 pin 1

HD2 pin 2

HD2 pin 3

HD2 pin 4

HD2 pin 5

HD2 pin 6

HD2 pin 7

HD2 pin 8

Function

Alarm 1

0v

Alarm 2

0v

Alarm 3

0v

Alarm 4 0v

WARNING: Electrical Danger: Ensure all power is disconnected before opening or working upon any Power Supply Unit.

Installation must be carried out by suitably qualified persons & all local safety regulations should be followed.

After removal of the lid take care of components C7, C9 and IC2 heatsink. In normal operation these components can reach a temperature of 55 Deg C.

To install the MIC-IR-240PSU and MIC-IR-115PSU please do the following:-

1. Locate the mounting position of the MIC-PSU so that it cannot be

interfered with either intentionally or accidentally, a lockable cabinet is

recommended.

Table K –IR Lamp Connections HD6

Composite cable Wire colour.

Brown

Grey

Function

IR Lamp

+

IR Lamp -

Terminal

Box

Connector

HD6-1

HD6-2

Terminal

box ID

marking.

IR+

IR-

2.

Securely fix the MIC-PSU using M4 stainless steel screws & washers;

 

ensure the cable glands have sufficient room to allow for the cables to

 

enter.

3.

Feed all cabling through the appropriate sized gland holes.

4.

Connect the composite cable to HD3 following the colour coding as shown

 

in the Table B & printed on the PCB, connect all wires.

5.

Connect the Brown and Grey wires for the IR lamps to HD6 as per Table J

Table L –Washer Pump Connection HD7

6.

Connect the Coaxial video cable to the CN1 header.

7.

If alarms are to be used connect these to HD2 as per Table I above

 

Signal

 

Connection

 

 

 

HD7 pin 1

 

 

 

 

Washer pump Live

 

 

 

 

HD7 pin 2

 

Washer pump Neutral

 

 

 

 

 

Ident

L

N

8.

Telemetry connections are provided by headers HD3, HD4 and HD5 which

 

respectively enable crimp or screw terminations for connecting the MIC400

 

to the control room.

9.

Connect the power to HD1 carefully observing the polarity and voltage as

 

per Table A.

Bosch Security Systems

Issue 1

Page 23
Image 23
Bosch Appliances MIC400AL Table K -IR Lamp Connections HD6, Terminal Box ID Marking, Table L -Washer Pump Connection HD7