MIC400 Series Camera Installation and Operation Manual

Connecting the MIC-USB485CVTR, USB to RS485 Converter

EN 29

Table Q – MIC-USB485CVTR Connection Table and Diagram

The MIC-USB485CVTR is a USB to RS485 signal converter that allows PCs without a serial port to connect directly to the MIC400 series camera via the telemetry connection (HD4) in the power supply, the MIC-USB485CVTR can also be used to connect a PC to any other RS485 device.

The MIC-USB485CVTR has been designed to work with all functions in Universal Camset and to be backwards compatible with legacy version of Camset although full compatibility is not guaranteed.

The MIC-USB485CVTR should be connected to the telemetry header (HD4) of the MIC400 power supply with Standard Twisted Pair cable such as Belden 8760.

The table overleaf shows how the screw terminal connections on the MIC- USB485CVTR connect to the MIC power supply depending upon the protocol and selected communication mode you may only need a 2 wire configuration.

CAUTION: Should be taken to avoid earth loops when connecting 0v from the converter to GND terminal in the MIC power supply

 

 

 

 

 

 

 

 

MIC Power Supply

 

 

Converter Output

 

Telemetry Header

 

 

 

 

(HD4 or HD5)

 

 

 

 

 

 

 

 

 

 

 

 

RxB / Rx -

 

TxB

 

 

 

 

 

 

 

 

 

 

 

 

RxA / Rx +

 

TxA

 

 

 

 

 

 

 

 

 

 

 

 

GND / 0V

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

TxA / Tx -

 

RxA

 

 

 

 

 

 

 

 

 

 

 

 

TxB / Tx +

 

RxB

 

 

 

 

 

 

 

 

 

 

 

Communication Mode

Full Duplex (4-wire only)

Shield (always)

Simplex

Half Duplex (2-wire)

Full Duplex (4-wire)